The Shieldmaster Ventilated firestop plate should be used when passing through a ceiling. The slots cut out of the plate allow for cool air to ventilate between the floors of the property whilst preventing the spread of fire. For compliance with the building regulations, a ventilated plate must be used.
Please see our Technical Information section for easy to understand guides for all the Building Regulations involved with stoves and flues.
For more information about twin wall flue installations, see our guide.
- Distance to Combustibles: 60mm
- Brand: Shieldmaster
- Warranty: 25 Years
- Finish: White
- Hole Diameter: 200mm
- Plate Dimensions: 360mm x 360mm
- Grade of Steel: 304 External
- Thickness of Steel: 0.5mm
- Temperature Resistance: 450°C
- Approvals: HETAS ANC112, BS 476-20, CE, EN 1856-1:2009
- Designation: T450-N1-D-Vm-L50050-G60